Texas Well Water Quality Atlas
Do private wells in Texas have more nitrate than public wells?
Yes. Among wells tested since 1992, nitrate exceeded the limit in 8.5% of domestic wells (272 of 3,202) and 1.8% of public-supply wells (61 of 3,310). Comparing wells of the same aquifer, depth and period, the gap narrows to 8.3% against 4.0% and does not disappear. Home wells are about half as deep: a median of 254 feet against 550.
Data: Texas Water Development Board Groundwater Database, file of November 13, 2026; Water Quality Portal (USGS and EPA), download of November 15, 2026. Page published November 16, 2026.
The figures
- Domestic wells above the nitrate limit
- 8.5%
- 272 of 3,202
- Public-supply wells
- 1.8%
- 61 of 3,310
- Comparing similar wells
- 8.3% / 4.0%
- gap 4.4 points (2.0 to 6.8)
- Wells under 100 ft, domestic
- 27.4%
- 121 of 442
- Wells under 100 ft, public
- 27.0%
- 27 of 100
- Median depth, domestic / public
- 254 / 550 ft
Nitrate above 10 mg/L as nitrogen
| Which wells | Domestic | Public supply | Gap in points (95% interval) | Times (95% interval) |
|---|---|---|---|---|
| All wells | 8.5% | 1.8% | 6.7 (4.5 to 9.2) | 4.6 (3.1 to 7.4) |
| Only where both kinds exist | 8.3% | 1.9% | 6.5 (3.8 to 8.8) | 4.4 (2.7 to 6.6) |
| Same mix of aquifer, depth and period | 8.3% | 4.0% | 4.4 (2.0 to 6.8) | 2.1 (1.4 to 3.5) |
The same comparison for the other substances
Arsenic above 10 µg/L
| Which wells | Domestic | Public supply | Gap in points (95% interval) | Times (95% interval) |
|---|---|---|---|---|
| All wells | 6.9% | 4.5% | 2.4 (0.3 to 4.7) | 1.5 (1.1 to 2.1) |
| Only where both kinds exist | 6.8% | 4.4% | 2.4 (0.0 to 4.9) | 1.5 (1.0 to 2.2) |
| Same mix of aquifer, depth and period | 6.8% | 6.5% | 0.3 (-2.3 to 2.5) | 1.1 (0.7 to 1.5) |
With the same mix the arsenic gap is 0.3 points, with an interval from −2.3 to 2.5: the data cannot tell the two kinds apart.
Total dissolved solids above 1,000 mg/L
| Which wells | Domestic | Public supply | Gap in points (95% interval) | Times (95% interval) |
|---|---|---|---|---|
| All wells | 21.9% | 8.5% | 13.4 (10.1 to 16.8) | 2.6 (2.1 to 3.2) |
| Only where both kinds exist | 22.6% | 8.3% | 14.2 (10.3 to 17.5) | 2.7 (2.1 to 3.4) |
| Same mix of aquifer, depth and period | 22.6% | 11.3% | 11.2 (7.5 to 15.2) | 2.0 (1.6 to 2.8) |
Fluoride above 4 mg/L
| Which wells | Domestic | Public supply | Gap in points (95% interval) | Times (95% interval) |
|---|---|---|---|---|
| All wells | 4.1% | 2.2% | 1.9 (0.6 to 3.3) | 1.9 (1.2 to 3.1) |
| Only where both kinds exist | 4.2% | 2.1% | 2.1 (0.5 to 3.6) | 2.0 (1.2 to 3.3) |
| Same mix of aquifer, depth and period | 4.2% | 2.7% | 1.5 (-0.4 to 2.9) | 1.5 (0.9 to 2.7) |
What this shows and what it doesn't
- It describes; it does not say why they differ.
- About 15% of the domestic wells fall outside the comparison of similar wells, because no public well shares their aquifer, depth and period.
- In wells under 100 feet the two kinds look alike: 27.4% of domestic and 27.0% of public wells. Depth explains part of the gap.
- Tested wells are not a random sample of either kind.
Test your own well
No map or table can say what is in the water of one well. These figures say how often the tested wells of an area went over a limit; the only way to know your well is to have its water tested by an accredited laboratory.
The drinking-water standards used here apply to public water systems. No law requires a private well to meet them: here they are only the yardstick.
Sources you can check
- Texas Water Development Board, Groundwater Database. File of November 13, 2026: the core of every figure. How the state explains its database.
- Water Quality Portal (USGS and EPA), download of November 15, 2026: well sites in Texas, after removing duplicates of state records.
- This dataset on Zenodo: the CSV files, a README with the method, the license and checksums. DOI 10.5281/zenodo.24287393.
Check it yourself
- Download the CSV (cifras-estado_statewide-figures.csv): every figure on this page is a cell of the open files.
- The same files are archived on Zenodo with checksums, so you can confirm a copy is unchanged.
- If a figure does not match, write to us with the number: we correct it and say so.
How we got it
Three populations, named each time: all classified domestic and public wells; only the cells of aquifer, depth band and period that have both; and in those cells, public wells reweighted to the mix of the domestic ones. Intervals from 2,000 resamples of 50 km blocks.
Each well counts once, with its most recent accepted test since 1992. Tests from the state database and the federal Water Quality Portal are merged after removing duplicates, with rules written before any result was compared with a limit.
The full method · All open data
How to cite this
Blanco, R. (2026). "Do private wells in Texas have more nitrate than public wells?." Texas Well Water Quality Atlas. TerraFunded. https://terrafunded.com/water-quality/findings/private-vs-public-wells-nitrate. Data: https://doi.org/10.5281/zenodo.24287393
Free to use with credit under CC BY 4.0. Please also credit the Texas Water Development Board. Dataset DOI: 10.5281/zenodo.24287393.
More questions
How common is arsenic in Texas well water?
Among 10,379 Texas wells with arsenic tested since 1992, 742 (7.1%) exceeded the 10 µg/L drinking-water limit in their most recent test.
Where is nitrate highest in Texas wells?
Among 11,026 Texas wells with nitrate tested since 1992, 697 (6.3%) exceeded 10 mg/L as nitrogen in their most recent test.
How common is fluoride above the limit in Texas well water?
Among 10,964 Texas wells with fluoride tested since 1992, 427 (3.9%) exceeded the 4 mg/L drinking-water limit in their most recent test, and 2,078 (19.0%) were above the 2 mg/L secondary level.
How salty is Texas well water?
Nearly one in four tested Texas wells (2,434 of 10,656, 22.8%) had more than 1,000 mg/L of total dissolved solids in its most recent test since 1992.
Is the county figure a good guide to the water in my well?
No: tested wells within 15 miles had 10.6% less error than the county figure for arsenic.
How often should I retest my Texas well water?
Near the limit, yes: 23% of wells with 8 to 10 µg/L of arsenic exceeded it later. Far from it, about 1% changed.
Which Texas counties have no well water quality data?
Archer, Rockwall, Shackelford and Stephens: no well tested for arsenic or nitrate since 1992.

Rodrigo Blanco, Founder and CEO of TerraFunded, a Texas company that sells rural land. These pages carry no listings, prices or offers.
Reviewed by two AI models in six rounds and checked with three independent programs; not yet reviewed by outside specialists.